Electric Bypass Switch for Distribution Line Applications
Electric bypass switch for distribution line work and utility maintenance. Compact design and practical field use support upgrades, service continuity, and engineering applications.
As a professional manufacturer of Electric Bypass Switch, we provide more cost-effective products. Whether you want to buy or become a distributor, you are welcome to contact us anytime.
Electric bypass switch is designed for distribution line applications that require dependable switching support, compact structure, and practical use in utility environments. This electric bypass switch is suitable for maintenance work, network upgrades, and engineering projects where controlled switching and service continuity are important. The product layout helps support organized installation and convenient access during field use.
For distributors, contractors, and utility buyers, the electric bypass switch offers a useful option for branch line work, project retrofits, and day-to-day distribution system support. It is built for customers seeking stable performance together with a practical equipment profile that fits project-based applications. The structure is suitable for installations where space efficiency and operational convenience both matter.
This electric bypass switch provides a balanced combination of reliable design, project adaptability, and cost-effective sourcing value. It is well suited to customers looking for distribution switching equipment for long-term cooperation and repeat purchasing needs.
Section |
Item | Detail | 12 kV | 24 kV |
| Model Selection | 200 A | Manual Operation | DPSW-FLW-12/T200-40 | DPSW-FLW-24/T200-40 |
| Model Selection | 200 A | Electric Operation | DPSW-FLW-12/200-40 | DPSW-FLW-24/J200-40 |
| Model Selection | 400 A | Manual Operation | DPSW-FLW-12/T400-40 | DPSW-FLW-24/T400-40 |
| Model Selection | 400 A | Electric Operation | DPSW-FLW-12/J400-40 | DPSW-FLW-24/J400-40 |
| Technical Specifications | Rated Current | — | 400/200 A | 400/200 A |
| Technical Specifications | Rated Frequency | — | 50/60 Hz | 50/60 Hz |
| Insulation Performance | Rated Impulse Withstand Voltage | Phase-to-Ground | 75 kV | 125 kV |
| Insulation Performance | Rated Impulse Withstand Voltage | Between Terminals of the Same Phase | 95 kV | 145 kV |
| Insulation Performance | Rated Power-Frequency Withstand Voltage | Phase-to-Ground | 42 kV | 64 kV |
| Insulation Performance | Rated Power-Frequency Withstand Voltage | Between Terminals of the Same Phase | 48 kV | 79 kV |
| Switching Current Capability | Load Current | — | 400/200 A | 400/200 A |
| Switching Current Capability | Magnetizing Current | — | 21 A | 21 A |
| Switching Current Capability | Cable Charging Current | — | 25 A | 25 A |
| Switching Current Capability | Line Charging Current | — | 1.5 A | 1.5 A |
| Technical Specifications | Rated Short-Time Withstand Current | — | 16 kA / 3 s | 16 kA / 3 s |
| Technical Specifications | Rated Closing Current | — | 50 kA | 50 kA |
| Gas Pressure | Rated Pressure | — | 0.5 ± 0.1 kgf/cm² | 0.5 ± 0.1 kgf/cm² |
| Gas Pressure | Explosion-Proof Pressure | — | 4–6 kgf/cm² | 4–6 kgf/cm² |
| Technical Specifications | Manual Operating Force | — | 176 ± 19 N | 176 ± 19 N |